Jul 20, 2021
Card Type: | Wiegand |
Number of Bits: | 32 |
Number of bits to sum for even parity: | 0 |
Address to start from: | 0 |
Number of bits to sum for odd parity: | 0 |
Address to start from: | 0 |
Number of Facility Code bits: | 0 |
Address to start from: | 0 |
Number of Cardholder ID bits: | 32 |
Address to start from: | 0 |
Number of Issue Level bits: | 0 |
Address to start from: | 0 |
. |
Step parity calculation by 2 bits
Suppress Facility Code Checking
37 bit Parity Test with 4 Parity Bits
37 bit Parity Test with 2 Parity Bits
Special 48 Bit Formatting (PIV)
Interpret card field as a Large Encoded Card ID (PIV-I)
How to Apply a Card Format Within Access It! Universal.NET
WaveLynx readers can use mobile credentials via the MyPass phone app. Without support for a facility code, the value -1 should be used when creating cards. It it advised to adjust a reader's offline mode to be a value other than Facility Code Only as any phone credential can be used when the reader is offline from the SCP controller.