ASSA ABLOY Remote Authentication


Overview

Beginning in Access It! Universal.NET 5.2 support has been added for the remote authentication feature. When enabled, this will force the lockset to awake upon any access denied event, confirm if the credential has access, and then grants access. This is beneficial when adding in new credentials prior to them being downloaded into the lockset. To enable this feature:

  1. Click Main
  2. Click Hardware
  3. Select IP Locksets
  4. Edit the IP lockset that is to use the remote authentication feature
  5. Select the Behavior tab
  6. Select (check) the Remote Authentication checkbox
  7. Click Save

More Information 

By default the lock will timeout if not able to reach the host within 15 seconds. To extend this time a DWORD registry value named "RemoteAuthenticationTimeout" can be created under HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\AMT\InstalledOCS's\AHG 420 OCS. Enter the value in seconds (decimal).