Allegion AD 300 Series


Overview

This document outlines how to program and integrate an Allegion AD-300 series lock to Access It!® Universal.

Access It! Universal.NET Licensing
The following licensing option must be enabled within the Access It! Universal.NET dongle and is a per integrated reader count license.

  • Integrated Reader Count - 1/x

Required Components

The following components are required to complete the integration.

  • Access It!® Universal min s/w v3
  • EP-2500 min f/w 1.148
  • HHD-Kit
    Windows CE device with Schlage Utility Software (SUS) pre-loaded, and USB cable included.
  • AD-300 Series lock

Hardware / Wiring References

For performance reasons, it is strongly recommended that no more than 8 AD-300 locksets be connected to a single RS-485 communication port.

EP-2500 Channel (Port 2 or 3) AD-300
TR+ TDA-
TR- TDB+
GND GND
.

Configuring a MUX-8 with the AD-300

While not required, users can make use of the MUX-8 multiplexer panel to allow wiring in a star topology. The only requirement is that the MUX-8 have dip switches 1, 2, and 4 OFF, and 3 ON.

Configuring The AD-300

  1. Connect the USB cable to the AD-300 and Handheld Device (HHD) running SUS
  2. On the HHD, launch SUS
  3. Login as Manager
    Default password is 123456.
  4. Press the Schlage button twice
  5. If successfully connected, the AD-300 will be listed
  6. Select Device Options
  7. Select Lock Properties
  8. Select the Edit tab
  9. Select the RS-485 Address field
  10. Assign an address to the AD-300
    All SIO devices wired to the EP-2500 need to be uniquely addressed between 0 and 31.
  11. Select Save
  12. Select OK
  13. Select Back
  14. Close SUS
  15. Disconnect the USB cable from the AD-300 and the HHD
  16. Wire the AD-300 to the EP-2500
    See the Hardware / Wiring References table.

Access It! Universal

  1. Install and configure the EP-2500 to communicate with Access It!® Universal.
  2. From the file menu, select Go | Main | Hardware
  3. Select SCP’s
  4. Edit the EP-2500
  5. Set Port speed to 9,600 for appropriate port
    The EP Channel that the PIM400-485s wired to.
  6. Set Protocol to Schlage PIM for appropriate port
    The EP Channel that the PIM400-485s wired to.
  7. Click Save
    The EP 2500 board will reset.
  8. From the left hand tree, expand SCP’s
  9. Expand the EP-2500
  10. Select SIOs
    Do not expand.
  11. From the right hand pane, edit the SIO that has the address of the AD-300
    See step 9 of Configuring the AD-300.
  12. Name the AD-300
  13. Set Model to Schlage PIM Gateway
  14. Check Device Installed
  15. Set Channel accordingly
    The EP Channel that the PIM400-485s wired to.
  16. Select the Options tab
  17. Set Number of Readers to 1
  18. Click Save