Aperio 1:8 Hub


Overview

The ASSA ABLOY Aperio 1:8 Hub allows for up to eight Aperio locksets to communicate to an Aperio Hub via a 2.4 GHz signal. Prior to installing the Aperio Hub within Access It! Universal, it must first be pre-programmed and have a lock associated to it using the Aperio Programming Application. The Aperio Hub must be running firmware allowing for Mercury protocol support. This information is displayed in the Aperio Programming Application.

For more information on the Aperio Programming Application, please contact (800) 810-WIRE.
The Aperio 1:8 Hub makes use of an OEM Code which must match that of RS2 Technologies. Hubs purchased through RS2 Technologies are already set accordingly.

Access It! Universal Licensing

The following licensing option must be enabled within the Access It! Universal dongle and is a per integrated reader count license.

  • Integrated Reader Count - 1/x

Required Components

The following components are required to complete the integration.

  • Access It!® Universal min s/w v3
  • EP series controller 

Supported Reader Modes

  • Unlocked
  • Locked
  • Facility Code Only
  • Card Only
  • PIN Only
  • Card AND PIN
  • Card Or PIN
  • 2 Card Mode

Hardware Configuration

RS-485 Wiring

The Aperio Hub communicates via the SCP RS-485 downstream communication.

Aperio Hub RS-485 Bus
A TR+
B TR-
.

Addressing

The Aperio software must have the DIP SWITCH setting enabled (checked).
The Aperio Hub must be uniquely addressed between 1 and 15.
Address 0 cannot be used.

Dip Switch Settings

Address Dip 1 Dip 2 Dip 3 Dip 4 Dip 5* Dip 6 Dip 7 Dip 8† Dip 9* Dip 10‡
1 On Off Off Off - Off Off Off - On
2 Off On Off Off - Off Off Off - On
3 On On Off Off - Off Off Off - On
4 Off Off On Off - Off Off Off - On
5 On Off On Off - Off Off Off - On
6 Off On On Off - Off Off Off - On
7 On On On Off - Off Off Off - On
8 Off Off Off On - Off Off Off - On
9 On Off Off On - Off Off Off - On
10 Off On Off On - Off Off Off - On
11 On On Off On - Off Off Off - On
12 Off Off On On - Off Off Off - On
13 On Off On On - Off Off Off - On
14 Off On On On - Off Off Off - On
15 On On On On - Off Off Off - On

*Dips 5 and 9 are not used.
†Dip 8 must be ON when the Aperio is the last device in the RS-485 bus.
‡Dip 10 must be OFF when using an external Antenna.

Software Configuration

  1. Launch Access It! Universal
  2. Select Go | Main | Hardware from the file menu
  3. Expand SCPs
  4. Expand the SCP the Aperio Hub is wired under
  5. Select SIO’s
  6. Edit the address of the Aperio SIO from the right hand pane
  7. Check the box Device Installed
  8. Set the Model to Aperio 1 To 8 Hub
  9. Select the Options tab
  10. Set the Number of Readers accordingly
  11. Click Save