The reader is normally secure and the inside lever/REX always allow for free egress. Allows for a single swipe of any valid card to toggle the reader between Unlocked/Locked. In order to use this feature, the Enable Double-Card Event option within the Reader Settings tab must be selected (checked). Pressing the specified Interior Push Button SIO/Input will re-lock the door.
The Apartment functionality operates during the Always Timezone and does not respect Card Groups. If this feature is needed to operate during a limited schedule, or respect Card Groups, separate Tasks should be created.
Mercury Readers
EP Firmware 1.18X firmware required.
- Within Access It! Universal V4.x, navigate to the Hardware Tree (Go | Main | Hardware)
- Select Installed Readers
- Edit the Reader that will be using the Apartment Extended Feature
- Select the Reader Settings tab
- Select (Check) the option Enable Double-Card Event
- Select the Extended Feature tab
- Select the Extended Feature Type Apartment
- Click Save
Interior Push Button settings do not apply to this extended feature.
Allegion AD 300/400 Readers
- Within Access It! Universal V4.x, navigate to the Hardware Tree (Go | Main | Hardware)
- Select Installed Readers
- Edit the Reader that will be using the Apartment Extended Feature
- Select the Reader Settings tab
- Select (Check) the option Enable Double-Card Event
- Select the Extended Feature tab
- Select the Extended Feature Type Apartment - Schlage
- Click Save