Overview

With Access It! Universal V4, there is now the ability to select which inputs/outputs will be used as the reader's Door Contact/REX/Strike. This functionality applies to the M5 hardware which has no inputs/outputs on certain reader boards, as well as all traditional Mercury hardware.

Implementation

  1. Navigate to the Hardware tree (Main | Hardware)
  2. Select Installed Readers
  3. In the right hand pane, edit the reader requiring a custom mapped Door Contact/REX/Strike
  4. Select the Door Settings tab
  5. To map a custom Door Contact, select the SIO containing the custom Door Contact from the SIO pick list
  6. Select the appropriate input number in the Input # pick list
  7. To map a custom Request to Exit (REX), select the SIO containing the custom REX from the SIO pick list
  8. Select the appropriate input number in the Input # pick list
  9. To map a custom Door Strike, select the SIO containing the custom Door Strike from the SIO pick list
  10. Select the appropriate output number in the Input # pick list
  11. Click Save