Starting with version 4 of Access It! Universal now supports the ability to communicate to Honeywell System Controllers and sub panels. The list of supported hardware is in the table below.
Mercury SIOs are not able to be added as SIOs to the Pro-Watch or WIN-PAK SCPs.

Access It! Universal Licensing

The following licensing option must be enabled within the Access It! Universal dongle and is a system wide option and per integrated reader count license.

  • Mercury PW/PRO Hardware - Yes
    *Included in DE-HNWL-INATE

  • Integrated Reader Count - 1/x

Implementation

Pro-Watch System

Part Number Description RS2 Equivalent Notes
PW6K1IC Controller EP-2500 F/W 2.78
PW6K1ICE Controller EP-1501/EP-1501 PLUS Use model EP-1501/EP-1501 PLUS within Access It! Universal.NET
PW5K1IC Controller SCP-E F/W 2.92*
PW3K1IC Controller MINI-SCP F/W 2.92*
PW5K1R1 1 Reader Interface Board MR-50 Series 1 N/A
PW6K1R1 1 Reader Interface Board MR-50 Series 2 N/A
PW5K1R2 2 Reader Interface Board MR-52 Series 1 N/A
PW6K1R2 2 Reader Interface Board MR-52 Series 2 N/A
PW5K1IN 16 Input Board MR-16 IN Series 1 N/A
PW6K1IN 16 Input Board MR-16 IN Series 2 N/A
PW5K1OUT 16 Output Board MR-16 OUT Series 1 N/A
PW6K1OUT 16 Output Board MR-16 OUT Series 2 N/A
.      

WIN-PAK System

Part Number Description RS2 Equivalent Notes
PRO22IC Controller MINI-SCP F/W 2.92*
PRO32IC Controller EP-2500 F/W 2.78
PRO22R1 1 Reader Interface Board MR-50 Series 1 N/A
PRO32R1 1 Reader Interface Board MR-50 Series 2 N/A
PRO22R2 2 Reader Interface Board MR-52 Series 1 N/A
PRO32R2 2 Reader Interface Board MR-52 Series 2 N/A
PRO22IN 16 Input Board MR-16 IN Series 1 N/A
PRO32IN 16 Input Board MR-16 IN Series 2 N/A
PRO22OUT 16 Output Board MR-16 OUT Series 1 N/A
PRO32OUT 16 Output Board MR-16 OUT Series 2 N/A
       

*Non-EP (legacy controllers) with firmware prior to v2.x must be multi-step updated to v2.90 then v2.92.

Beginning in Access It! Universal.NET v7, minimum firmware 2.114 is required.

Feature Comparisons

  • Honeywell supports up to 128 Reader/Timezones per Access Level. RS2/Mercury supports up to 64 Reader/Timezones per Access Level.
  • Honeywell keypad user commands end with pressing the # (Enter) key. RS2/Mercury keypad user commands end with pressing the * (Clear) key.
  • Honeywell duress PIN codes can be accessed by +1/-1 of the PIN number. RS2/Mercury duress PIN codes can be accessed by +1 of the PIN number.
  • Access It! Universal does not support AES 128 bit encryption for PW3K1IC and the PRO22IC (MINI-SCP) controllers.

Firmware Files

Should a field panel require a firmware update, please contact RS2 Technical Support.

Internal KB Article 551 contains a link for the Honeywell firmware entitled ProWatch and WinPAK Firmware.zip.