EP/MINI-SCP Dialup Configuration


Host – Modem Setup

Windows 7

  1. Within the Windows 7 Start Menu, search for Phone and Modem
  2. Select Phone and Modem
  3. Select the Modems tab
  4. Select Add
  5. Click Next
  6. Windows will locate and install the U.S. Robotics driver
  7. Click Finish
  8. With Modem selected, click Properties
  9. Select the Modem tab
  10. Set Maximum Port Speed to 19200
  11. Select the Advanced tab
  12. Select Change Default Preferences
  13. Set Port Speed to 19200
  14. Set Data Protocol to Disabled
  15. Set Compression to Disabled
  16. Set Flow Control to Hardware
  17. Select the Advanced tab
  18. Set Data Bits to 8
  19. Set Parity to None
  20. Set Stop bits to 1
  21. Set Modulation to Standard
  22. Click OK
  23. Click OK
  24. Click OK

SCP – Modem Setup
EP-1502 / EP-2500
Wiring

Wire Color 5 Pin Block
Red TXD
Black RXD
White CTS
Green GND
.  

Configuration

  1. Set S1 – Configuration DIP Switch Dip 2 ON
  2. Set S1 – Configuration DIP Switch Dips 1,3, & 4 OFF
  3. Apply power to the EP-1502/2500
  4. Manually configure a computer to 192.168.0.100
  5. Using a crossover cable, connect computer to EP-1502/2500
  6. Open a web browser and go to 192.168.0.251
  7. Set S1 – Configuration DIP Switch DIP 1 ON
  8. Click on Click Here to Login
  9. Click on Continue to this website (not recommended).
  10. Enter a Username of admin
  11. Enter a Password of password
  12. Click Host Comm from the left hand menu
  13. Change Communication Address to 1
  14. Change Connection Type to Serial-Modem
  15. Change Baud Rate to 38400
  16. Change Date Security to None
  17. Click Accept
  18. Click Apply Settings from the left hand menu
  19. Click Apply Settings, Reboot
  20. Wait 60 seconds for the EP-1502/2500 to reboot
  21. Remove power from the EP-1502/2500
  22. Set all S1 Configuration DIP Switch Dips OFF
  23. Remove crossover cable from EP-1502/2500
  24. Apply Power to EP-1502/2500
  25. Configure Access It! Universal accordingly

MINI-SCP
Wiring

Wire Color 5 Pin Block
Red TXD1
Black RXD1
White CTS1
Green GND
.  

Configuration

  1. Set DIP Switch Dips 1,5,6,7 ON and Dips 2,3,4, and 8 OFF
  2. Set JP 3,4,5,6,9 to 232
  3. Set JP7 to 2W
  4. Apply power to the MINI-SCP

  • 2
  • 11-Apr-2017
  • 4942 Views