Overview

The ASSA ABLOY AH20 Hub allows for a single Aperio lockset to communicate to an Aperio Hub via a 2.4 GHz signal. Prior to connecting the AH20 Hub to the appropriate reader port, it must first be pre-programmed and have a lock associated to it using the Aperio Programming Application.

For more information on the Aperio Programming Application, please contact (800) 810-WIRE.

Hardware Configuration

Wiring

The Aperio AH20 Hub communicates via a Wiegand signal to the reader port of the SCP/SIO.

Aperio Hub Reader Port
DATA 1 CLK/D1
DATA 0 DAT/D0
GREEN LED
GND GND
8-24VDC VO

More Information

  • As the hub will output a Wiegand signal to the reader port of the SCP/SIO, use of the AH20 is entirely transparent to the Mercury hardware. 
  • Dip Switch Number 1 on AH20 controls use of LED Red signal for access decision. If landing Aperio Hub Connector GREEN on LED, this dipswitch should be set to OFF. 